Projects and portfolio

HVAC and refrigeration work, photographed on site.

Recent installations, repairs and maintenance across Lusaka and the Copperbelt, documented with the equipment involved and the scope carried out.

Recent works

Every record shows the equipment, the scope and the photographs.

Browse by region, or open any record for the full job sheet.

Split unit condenser installations and commissioning — Lusaka — photograph 1
01Residential

Split unit condenser installations and commissioning

Location
Lusaka
Equipment
Split system outdoor condenser units

Outdoor condenser units installed on galvanised wall brackets and raised concrete plinths so the coil faces stay clear of ground water, gravel and debris. Refrigerant pipework was run in conduit and finished with insulated, taped joints, condensate drainage routed clear of the wall, and each unit pressure tested and run-tested before handover. Bracket and plinth mounting also keeps the service access panels reachable for future maintenance.

Completed
View the full job sheet
Outdoor condenser servicing and coil cleaning — Lusaka — photograph 1
02Offices

Outdoor condenser servicing and coil cleaning

Location
Lusaka
Equipment
Wall-mounted split air conditioning units

A scheduled service on wall-mounted split systems. Condenser coils, fan blades and housings were cleaned of the dust and debris that choke airflow and push up running pressures, electrical terminations were checked, and operating pressures were read on a manifold gauge set to confirm the refrigerant charge. The photographs show the coil and fan assembly as found, the unit opened up during the service, and the outdoor unit being tested from a ladder.

Completed
View the full job sheet
Refrigerated container and commercial refrigeration service — Copperbelt — photograph 1
03Retail

Refrigerated container and commercial refrigeration service

Location
Copperbelt
Equipment
Refrigerated container (R404A) and commercial upright refrigeration

Evaporator and refrigeration work on a refrigerated container running R404A, covering inspection and cleaning of the ceiling-mounted evaporator fans and a check of the air path and drainage inside the box. Alongside it, maintenance of commercial upright refrigeration: a side-by-side unit with an integral ice and water dispenser and an upright freezer, with condenser cleaning, door seal checks and a temperature performance test.

Completed
View the full job sheet
Split system electrical fault finding and repair — Copperbelt — photograph 1
04Residential

Split system electrical fault finding and repair

Location
Copperbelt
Equipment
Split system condenser, electrical panel

An outdoor condenser opened up for fault finding on the control circuit. Wiring and terminal connections were inspected, the fault traced and repaired, and the unit reassembled and run-tested. Electrical faults on split systems commonly come from loose terminations, rodent damage or water ingress at the panel, so the wiring loom and gland entry are checked as part of the repair.

Completed
View the full job sheet

Next step

Planning a similar installation or upgrade?

Send us the equipment details and site information. We will assess the requirement and quote against a clear scope.